This article contains affiliate links: if you buy through them, Wanda-techs earns a commission at no extra cost to you.
Your pellet stove won’t light: the screen stays black, an ignition failure alarm appears, or the pellets drop into the burn pot without catching fire. The cause can be anything from the power supply to a dirty burn pot, damp pellets, weak draft or a faulty igniter. Start with the checks that need no tools, then move on to the technical ones.
Common symptoms and causes
- Dead screen: plug, main switch, circuit breaker or an internal fault.
- Ignition failure alarm: igniter, dirty burn pot, damp pellets, or weak draft picked up by the pressure switch.
- Pellets fall but no flame: igniter dead or badly positioned, dirty burn pot, blocked air intake.
- No pellets in the burn pot: empty hopper, jammed auger or a failed auger motor.
- Other causes: poor-quality pellets, badly set schedules, blocked flue, not enough ventilation in the room, faulty temperature sensor.
Before you start
Get an ash vacuum and the manual for your model. The manual always overrides the general advice in this guide.
Warning: unplug the appliance from the mains before opening it, and never work on a stove that is plugged in. The capacitors in some appliances (TVs, microwaves, power supplies) stay charged after unplugging: do not touch them.
On a pellet stove, shut it down with its normal procedure, wait for the shutdown cycle to finish and the stove to cool completely, and only then unplug it. Circuit boards, sensors and electrical parts are a job for a professional.
Warning: opening the appliance may void the warranty, so check when it ends first. Annual servicing and chimney sweeping are done by a professional who gives you a certificate, and your insurer may ask for it after an incident.
Warning: poor combustion or a faulty flue produces carbon monoxide (CO). If you smell smoke or anything unusual, shut the stove down and ventilate the room. The door gasket, the quality of the pellets and the ventilation then need checking.
Good to know: none of the steps in this guide erases your stove’s settings or schedules.
Solution 1: check the power supply and the schedules
A dead screen points first to the power supply. Do these checks with the stove cold.
- Check that the power cord is firmly plugged in, at the stove and at the wall outlet.
- Check at the electrical panel that the circuit breaker for that circuit is on.
- Set the stove’s main switch to
On. - Check that the heating schedules are enabled and set as the manual describes.
Expected result: the screen lights up and the stove starts its ignition cycle at the scheduled time or on demand.
Solution 2: clean the burn pot and the ash pan
The burn pot (also called the firepot) is the small tray where the pellets burn. Its air holes must stay clear.
- Shut the stove down with its normal procedure.
- Wait for the shutdown cycle to finish completely and for the stove to cool.
- Unplug the stove.
- Vacuum the ash pan, the area around it and the compartment behind it with an ash vacuum.
- Remove the ash from the burn pot.
- Check the condition of the burn pot and clear its air holes.
- Remove ash residue from the pot holder and from around the igniter.
- Clean or replace the air filter.
Expected result: the burn pot, the nozzles and the combustion chamber are clean, with no excess ash or soot. Plug the stove back in and try another ignition.
To vacuum up the cold ash from the pan and the burn pot, here is an ash vacuum with a metal canister.

Kärcher AD 2 ash vacuum cleaner, 14 L metal tank
Vacuums cold ash from the ash drawer, the burn pot and the combustion chamber without spreading it. Its 14-litre metal tank and pleated filter mean fewer trips to empty it.
- AmazonSee at Amazon

Good to know: how to clear the ignition failure alarm, and what to do with pellets left in the burn pot, depends on the model. Follow the manual before you restart.
Tip: cleaning the ash pan and burn pot is part of weekly maintenance. If your vacuum loses suction during the job, see our checks for a vacuum cleaner that won’t pick up.
Solution 3: check the pellets and how they are fed
The pellets travel from the hopper to the burn pot by an auger, a spiral rod turned by a motor (some models use an airlock feeder instead).
- Fill the hopper with pellets.
- Inspect the pellets: they should be dry and intact, with no moisture and no clinker.
- With the stove off, cold and unplugged, check that the path from the hopper to the burn pot is not blocked.
- At the next start, listen to the auger: a grinding or clicking noise means its motor needs checking.
Expected result: pellets drop into the burn pot at the start of the ignition cycle.
Good to know: the ideal moisture content of a pellet is around 8 to 10%. Buy and store your pellets as the stove manufacturer recommends.
If the auger or its motor seems to be the problem, leave the check to a technician.
Solution 4: clear the air intake and the flue
The combustion fan brings air to the fire and pushes the exhaust gases out. The pressure switch, a pressure sensor, checks that the draft reaches a minimum level. A dirty flue or a blocked air intake can trip it and put the stove into safety mode.
- With the stove cold, dust off the air intake and the ventilation grilles.
- Check that the flue pipe and the room’s ventilation are clear.
- With the stove off, cold and unplugged, check that the small tube connected to the pressure switch is neither blocked nor damaged.
Expected result: air flows freely and the pressure switch no longer puts the stove into safety mode at startup.
Check the air intake and the grilles every month. The door gasket is inspected by the professional during the annual service: a worn gasket can cause a smell. If the flue itself is dirty, call a chimney sweep.
Solution 5: test the igniter and the sensor
The igniter is a heating element in the burn pot that lights the pellets.
On a normal sequence, the pellets catch after roughly 2 to 7 minutes, the flame steadies within 5 to 8 minutes and the stove reaches its running mode in 7 to 15 minutes. The igniter switches off at around 7 minutes.
- Start an ignition and listen: you should hear a click at startup.
- Look into the burn pot: the igniter should glow red or light up.
- Compare what happens with the normal sequence: pellets lit after roughly 2 to 7 minutes.
- With the stove off, cold and unplugged, check the igniter’s position relative to the burn pot and that it is tight.
- With the stove off, cold and unplugged, check the temperature sensor: position, damage, dirt.
Expected result: the igniter glows, the pellets catch fire and the flame steadies.

An igniter that shows no sign of working needs replacing, by a professional or as the manual describes for your model. A damaged sensor can be replaced if needed.
More serious electrical faults (boards, sensors, thermostats) are a job for a specialist.
If nothing works
Stop if a new igniter and a clean burn pot change nothing, if the pressure switch, a sensor, the board or the auger seems to be at fault, if a smell of smoke persists, or at the slightest doubt. Then call a qualified technician or the brand’s customer service.
Have these to hand:
- the make, model and serial number of the stove;
- the purchase date and the invoice;
- the date of the last service and the latest chimney sweep certificate;
- a description of the symptom and the message shown on the screen.
Annual servicing by a certified professional is mandatory in France and is often required by manufacturers and insurers elsewhere, so check the rules where you live. It includes cleaning the heat exchanger, the burn pot and the exterior, and checking the gaskets, the igniters and the combustion settings.
Chimney sweeping is mandatory in France too and comes with a certificate. Its frequency varies by source: at least once a year according to a Jotul page, twice a year with one during the heating season according to its maintenance guide. Follow your stove’s manual.
If an electric heater is your backup while you wait for the technician and it stays cold, see what to check on an electric heater that won’t warm up.
Take better care of your pellet stove: our toolbox
Quality pellets, a carbon monoxide detector and a few maintenance accessories help prevent the next ignition failure.
- DINplus A1 wood pellets, 15 kg bagWood pellets for stoves, DINplus and ENplus A1 certified, in a 15 kg bag. Dry, low-ash pellets limit the build-up of ash in the burn pot.AmazonSee at Amazon
- X-Sense XC01-R standalone carbon monoxide detectorSounds an alarm when carbon monoxide builds up in a room, a gas you cannot see or smell. Useful near any heating appliance that burns fuel.AmazonSee at Amazon
- Pellet stove cleaning kit, flexible rod with 80 and 150 mm brushesA flexible rod takes two brushes, an 80 mm nylon one and a 140 mm steel-wire one, plus a universal brush and a dustpan. It cleans stove pipes and hard-to-reach corners.AmazonSee at Amazon
- Pro Insert glass cleaner for stove and fireplace inserts, 500 mlA foam that lifts soot and burnt-on deposits from the glass of an insert, stove or fireplace. It keeps the flame visible during ignition.AmazonSee at Amazon
Frequently asked questions
Why won’t my pellet stove light?
The causes range from running out of pellets to a failed part. Common ones are damp or poor-quality pellets, an electrical problem, badly set schedules, a dirty burn pot, a blocked flue or a lack of ventilation. A faulty igniter or sensor can also stop ignition.
How can I tell if my pellet stove igniter is dead?
A working igniter clicks at startup and glows red in the burn pot. If you see neither, check its position and that it is tight first. With no sign of working at all, the igniter needs replacing, by a professional or as the manual describes.
What should I do when the stove shows an ignition failure?
Go back through the checks in order: clean burn pot, dry pellets in the hopper, clear air intake, then the igniter. An ignition failure can come from the igniter, a dirty burn pot, damp pellets or weak draft picked up by the pressure switch. How to clear the alarm depends on the model and is in the manual; if the fault returns after these checks, call a technician.
How often should I clean a pellet stove’s burn pot?
Every week, with the stove cold. Check the condition of the burn pot, clear its air holes and remove the ash. The professional also cleans it during the annual service.
Share this content: