This article contains affiliate links: if you buy through them, Wanda-techs earns a commission at no extra cost to you.
Your electric radiator is not heating, whether the screen is dark or lit? Before you blame the thermostat, check the power supply, the mode and the set temperature, then any orders sent by a central programmer. A frost-protection mode, a set temperature below the room temperature or a load-shedding signal is enough to keep it cold.
Common symptoms and causes
- Dark screen: switch, circuit breaker, fuse or a display in standby.
- Indicator on but radiator cold: set temperature below the room temperature, eco mode or an eco time slot.
- Radiator stuck at 7 °C (about 45 °F): frost-protection, absence or summer mode, an open window detected, an order from the central programmer or load shedding.
- It heats, then stops: an open window detected because of a draught, load shedding, the schedule or presence detection; on an oil-filled radiator, the overheat cut-out.
- Faulty thermostat, control board or heating element: diagnosis by a professional.
Before you start
Keep your model’s manual within reach: the names of the modes and buttons change from one model to the next. Have a room thermometer ready.
Warning: unplug the appliance from the mains before opening it, and never work on a plugged-in appliance. Some appliances (TVs, microwaves, power supplies) hold a charge in their capacitors even after unplugging: do not touch them.
Here, never open the radiator. Do not touch the wiring or the pilot wire (the black cable that carries the orders of a central programmer) and do not measure any voltage: the connection is a job for a qualified person. Plug a portable heater into a wall socket, never into an extension lead or a power strip.
Warning: never cover the radiator, even briefly, and do not block its vents: there is a risk of overheating and fire. Its surface gets very hot, so keep flammable materials away.
Warning: opening the appliance may void the warranty, so check the warranty end date first. For an oil-filled radiator, a thermostat or a control board, go through the manufacturer’s customer service.
Solution 1: check the power supply and the switch
- At the electrical panel, check that the radiator’s circuit breaker has not tripped and that its fuse is intact.
- Set the appliance’s on/off switch to ON or 1. On a digital Thermor, it is at the back, on the right side of the unit.
- On an Atlantic Solius Néo, set the switch at the back of the control unit to position I.
- If the screen of an Atlantic Solius Néo stays black, press any button to wake the display from standby.
- On a digital Thermor in standby, hold the O button for about 15 seconds, choose the switch-on option and confirm with O. On some models, a 5-second press on ON/OFF is enough.
- Portable heater: push the plug firmly into a working wall socket, without an extension lead or a power strip.
- Unwind the cord completely and check that the cable and the appliance are not damaged.
- On a De’Longhi with a mechanical timer, leave the appliance plugged in and set the timer to the right time if it was unplugged.
Warning: the next step cuts the power and may erase the time, the date and the mode. On a Thermor, these settings are kept for only about 5 minutes after a power cut. Write them down first.
- On an Atlantic Solius Néo whose thermostat stays stuck, switch the radiator off at the circuit breaker or fuse for about 10 minutes, then switch it back on.
- Set the date, the time and the mode again if the appliance asks for them.
Expected result: the screen lights up and the appliance responds to the buttons. If the circuit breaker and fuse are fine and the radiator still gets no power, call an electrician.
Solution 2: check the mode and the set temperature
- Measure the room temperature with a room thermometer.
- Compare it with the set temperature (the temperature you asked for): if the room is already warmer, a cold radiator is normal.
- On a Thermor in frost-protection, absence or summer mode (fixed set temperature of 7 °C), change the mode.
- On an Atlantic Solius Néo in off or frost-protection mode, switch to comfort mode.
- On a Thermor in eco mode, check the eco set temperature: by default, the comfort temperature minus 3.5 °C (about 6 °F), according to your model’s manual.
- On an Atlantic Solius Néo in scheduled mode, check that the current time falls within a comfort time slot.
- On a Thermor running a schedule, set the temperature in basic mode or during a comfort period.
- If the buttons of an Atlantic Solius Néo do not respond, press and hold both arrow buttons to release the lock.
- Raise the set temperature above the room temperature.

Expected result: the heating indicator lights up and the radiator heats. On an Atlantic Solius Néo, this indicator lights up only while the heating element is powered.
Good to know: on a Thermor, a temperature set outside a comfort period is only an override, cleared at the next time slot. Presence detection changes the temperature without any action from you. That is not a fault.
If you do not have a room thermometer, here is one that also shows the humidity of the room.

ThermoPro TP49: indoor thermometer and hygrometer
Shows the room temperature and humidity on a small screen. Handy for comparing the real temperature with a heater setpoint.
- AmazonSee at Amazon
Solution 3: turn off an open-window detection that is too sensitive
After a sharp drop in temperature, Thermor and Atlantic radiators switch to frost protection, at 7 °C, without stating how long it lasts. The feature does not exist on every Atlantic model.
- Close the window and let the temperature rise.
- If the radiator stays in frost protection with the window closed, look for a cold draught around the sensor, at the bottom right of the appliance.
- Reduce that draught.
- If you cannot reduce it, turn the feature off by following your model’s manual.
- On an Atlantic Solius Néo, make this setting in the open-window detection menu.
- Once the feature is off, switch the radiator off by hand when you air the room.
Expected result: the radiator no longer drops back to frost protection while the window stays closed.
Good to know: the feature is not recommended in hallways or in rooms near an entrance door that opens onto the outside.
Solution 4: check the central programmer and load shedding
Load shedding is a heating cut ordered by a load-shedding device. When every radiator shows it, your consumption may be exceeding your subscribed power.
- On a Thermor, if the screen shows “DEL”, a load-shedding message, a frost-protection message or “7°C” and you cannot change the set temperature, go to the central programmer: the order comes through the pilot wire and takes priority.
- Check that the central programmer is not in absence, frost-protection or summer mode.
- Check the programmer’s date and time: the clock change is not automatic everywhere.
- With the Cozytouch app, check that the radiator is still paired.
- On a Thermor controlled by an external programmer, an energy manager or Cozytouch, set the appliance to its external-control or pilot-wire setting (the name depends on the model).
- If every radiator shows load shedding, switch off or unplug other appliances.
- On an Atlantic Solius Néo, check that the load-shedding device has not cut the appliance.
Expected result: the message disappears and the radiator follows its comfort and eco periods again. On a Thermor, outside pilot-wire mode, only the frost-protection and load-shedding orders are taken into account.
Warning: do not touch the pilot wire. If load shedding persists after the consumption peak, call an electrician.
Solution 5: switch off, let it cool down and dust it
Oil-filled radiator that no longer heats
The De’Longhi manual describes a safety device that switches the radiator off if it overheats.
- Switch the radiator off, then unplug it from the wall socket.
- Let it cool down.
- Remove whatever covers or blocks it.
- Clean it with a soft, slightly damp cloth, with no detergent or abrasive product.
- Plug it back directly into the wall socket and set a higher temperature if it was too low.

Expected result: the radiator starts heating again. If it does not restart, contact De’Longhi customer service.
Electric convector or fixed radiator
The official Atlantic and Thermor sources we consulted do not describe an overheat cut-out to reset on these appliances. Do not look for a button inside.
Warning: as in Solution 1, the power cut may erase the time, the date and the mode. Write them down first.
- Switch the radiator off with its switch, then unplug it or, if it is hard-wired, switch it off at the circuit breaker.
- Let it cool down.
- On a Thermor, dust the sensor on the front with a dry cloth, with the appliance still switched off.
- Plug it back in or switch the circuit breaker back on, then switch the radiator on.
- Set the date, the time and the mode again if the appliance asks for them.
Expected result: once switched on again, the radiator heats. If it stays cold, call a professional.
Good to know: according to Thermor, a radiator placed too close to the floor or in a recess regulates the temperature poorly.
If nothing works
Is everything in order and the radiator still cold? Stop there. A faulty thermostat or power board is replaced by the installer or the manufacturer’s customer service; on an oil-filled radiator, an oil leak or a damaged cable is a matter for the manufacturer.
Before you call, have these ready:
- the product reference and its serial number;
- the error code shown, if there is one;
- a description of the fault.
If the repair costs more than the appliance, here are two dry-inertia radiators to compare.
- Kalia Roswell 1500 W: dry-inertia ceramic electric radiatorRadiator with a ceramic block, LCD screen and programming. It gives off heat steadily for a medium-sized room.AmazonSee at Amazon
- Kalia 1000 W: dry-inertia ceramic electric radiator, glass frontRadiator with a ceramic block, glass front and LCD screen. Suits a small room or a bedroom.AmazonSee at Amazon
The same approach works for an oven that won’t heat or an air fryer that won’t heat.
Take better care of your heating: our toolbox
These accessories help you track the room temperature, cope with a breakdown and stay safe.
- ThermoPro TP49: indoor thermometer and hygrometerShows the room temperature and humidity on a small screen. Handy for comparing the real temperature with a heater setpoint.AmazonSee at Amazon
- De'Longhi TRDX40820E: 2000 W oil-filled radiatorPortable oil-filled radiator that keeps giving off heat after it switches off. Stands in for a fixed heater while it is being repaired.AmazonSee at Amazon
- X-Sense SD01: smoke alarm with escape light, 10-year batteryPhotoelectric smoke alarm that meets the EN 14604 standard, with a sealed 10-year battery. It adds protection to a heated room.AmazonSee at Amazon
- Sanggi: long flexible brush for condenser and radiatorLong, thin brush that reaches dust between fins and grilles. Use it with the appliance switched off.AmazonSee at Amazon
Frequently asked questions
Why is my electric radiator on but not heating?
A set temperature below the room temperature keeps it cold without any fault, in comfort mode as in eco mode. Measure the room with a thermometer, then raise the set temperature above it.
Why does my electric radiator stay in frost-protection mode?
A frost-protection, absence or summer mode, an order from the central programmer or a detected open window keeps it at 7 °C. On a Thermor, a 7 °C set temperature you cannot change comes from the pilot wire: check the central programmer. With the window closed, look for a draught around the sensor.
Does an electric radiator have an overheat cut-out?
Yes on De’Longhi oil-filled radiators: a device switches them off if they overheat. Switch them off, unplug them, let them cool and remove whatever covers them; if they do not restart, contact De’Longhi. For fixed radiators, the official Atlantic and Thermor pages we consulted do not describe one: cut the power, let it cool and call a professional.
How can I tell if an electric radiator’s thermostat is faulty?
Only a professional can confirm it, once the power supply, the mode, the set temperature and the schedule are ruled out. On an Atlantic, a gap between the sensor and the room can be normal: allow at least 6 hours for the temperature to stabilise. A faulty thermostat is replaced by the installer or the manufacturer’s customer service.
Share this content: