  1. Common symptoms and causes
  2. Before you start
  3. Solution 1: follow your brand’s cold-start procedure
    1. Honda HS720 (A, AM and AS versions)
    2. Husqvarna ST 224, ST 227 and ST 230
    3. Toro Power Max 724 OE and 826 OE
  4. Solution 2: battery-powered snow blower (EGO SNT2400)
  5. Solution 3: electric starter and frozen recoil rope
  6. Solution 4: replace stale gas
    1. Drain the carburetor on a Honda HS720
  7. Solution 5: check the spark plug
  8. If nothing works
  9. Take better care of your snow blower: our toolbox
  10. Frequently asked questions
    1. Why won’t my snow blower start after the summer?
    2. How do you start a snow blower in very cold weather?
    3. Should you drain the gas from a snow blower for the summer?
    4. How can you tell if a snow blower’s spark plug is bad?

This article contains affiliate links: if you buy through them, Wanda-techs earns a commission at no extra cost to you.

Your snow blower won’t start at the beginning of winter? Honda, Toro and Husqvarna manuals have you check the key, fuel valve, choke, primer, gas and spark plug. Briggs & Stratton notes that gas older than 30 days can keep an engine from starting.

Advertisement

Common symptoms and causes

  • The recoil starter pulls but the engine won’t catch: gas left over the summer, or deposits in the carburetor (the part that mixes air and gas).
  • Fuel valve closed (Honda, Toro, Husqvarna when the machine has one).
  • Choke or primer (the bulb you press with your thumb) misused on a cold engine, or an engine flooded by too much priming (Husqvarna, Toro).
  • Safety or ignition key missing (Husqvarna, Toro, Briggs & Stratton).
  • Spark plug cap off, or a fouled, pitted or badly gapped plug.
  • Oil level too low or too high (Toro, Briggs & Stratton).
  • Fuel cap iced over or its vent blocked (Toro, Briggs & Stratton).
  • Frozen recoil rope (Husqvarna).
  • Electric starter dead: no power at the outlet, or a faulty extension cord (Honda).
  • Battery-powered snow blower: battery at -4 °F (-20 °C) or colder, battery empty, or the safety button then trigger sequence not followed (EGO).

Before you start

Keep your model’s manual handy, since controls and primer pushes vary by model. Have fresh gas and a spark plug wrench ready.

Warning: stop the engine, remove the key and wait until the auger (the spiral at the front that picks up snow) and the impeller have stopped completely before you touch anything. Husqvarna and EGO say 10 seconds.

Warning: remove the spark plug cap before any check (Honda, Husqvarna). Never put your hands in the discharge chute, even with the engine off and even with gloves on: use the clean-out tool mounted on the machine (Toro, EGO) or a wooden stick (Honda).

Warning: never run the engine in an enclosed or partly enclosed space such as a garage, because of carbon monoxide (Honda). Keep the machine at least 3 ft (1 m) from walls.

Warning: handle gas outdoors, with the engine off and cool, away from any flame; vapors from stored gas can explode (Toro). Move the machine at least 10 ft (3 m) from the refueling spot before starting it (Honda, Husqvarna).

Warning: for the electric starter, use an outdoor-rated extension cord in good condition (Honda, Toro) on a grounded outlet (Husqvarna), never in the rain or with wet hands (Honda). Unplug the cord before any work; a machine left plugged in risks starting unintentionally (Toro).

Advertisement

Warning: never puncture, bend or heat a lithium battery. A swollen battery must not be recharged and goes to a collection point; work on a non-flammable surface. Remove the battery or batteries before clearing the chute (EGO).

Good to know: opening the machine can void the warranty, so check when it ends first. Honda also excludes gas above 10% ethanol and damage from stale gas.

Solution 1: follow your brand’s cold-start procedure

Every manufacturer has its own sequence; for another model, follow your manual.

Honda HS720 (A, AM and AS versions)

  1. Set the fuel valve exactly to ON.
  2. With the engine cold, pull the choke knob out to CLOSED.
  3. Set the engine switch to ON; on the AS version, turn the key to ON.
  4. Pull the recoil starter grip slowly until you feel resistance, then pull briskly.
  5. Ease the grip back gently.
  6. Warm up a few minutes, gradually pushing the choke toward OPEN.

The engine should run steadily with the choke at OPEN. The HS720 manual lists no primer. After use, set the fuel valve back to OFF (Honda).

Husqvarna ST 224, ST 227 and ST 230

  1. Push the ON/OFF key in until it clicks, without turning it.
  2. Slide the control lever to ON.
  3. Set the throttle to FAST.
  4. With the engine cold, set the choke lever to FULL.
  5. Press the primer: the manual gives 3 pushes in its electric-start procedure.
  6. Pull the starter rope, then let the handle back slowly without releasing it.
  7. Once the engine is running, slowly move the choke back to OFF.
  8. Idle 2 to 3 minutes before throwing snow.

Warning: too much priming floods the engine. Husqvarna says to wait a few minutes without priming, then restart at full throttle with the choke at OFF.

Toro Power Max 724 OE and 826 OE

  1. Check the oil level.
  2. Open the fuel shutoff valve by a quarter turn counterclockwise.
  3. Insert the ignition key.
  4. Press the primer firmly with your thumb, holding it in for 1 second each time: 2 times at 15 °F (-9 °C) or above, 4 times below that.
  5. Turn the choke to Choke.
  6. Set the throttle to Fast.
  7. Pull the recoil starter, or press the electric-starter button on the version that has one.
  8. After a few minutes, move the choke toward Run in stages, waiting for the engine to run smoothly before each adjustment.

The engine should run smoothly with the choke at Run. Other Toro Power Max models call for other numbers of primer pushes.

Advertisement
fraise-a-neige-ne-demarre-pas-1-1024x576 Snow Blower Won't Start: What to Check Before the Shop?
Choke, primer and throttle are set in the order your brand's manual gives.

Solution 2: battery-powered snow blower (EGO SNT2400)

Never bypass the safety button.

  1. Install the battery or batteries and close the cover until the latch snaps.
  2. Press and hold the safety button for 1 second: the indicator light blinks green.
  3. While the light is blinking, squeeze the auger trigger.
  4. If the machine won’t start in very cold weather, remove the battery.
  5. Leave it indoors at least 10 minutes, away from heat sources.
  6. Put it back in and repeat the sequence.

The auger should turn while you hold the trigger.

Solution 3: electric starter and frozen recoil rope

Only some versions have one, such as the Honda HS720 AS.

The times and plug-in order below come from Honda, Husqvarna and Toro manuals for North American models; for the cord, outlet and times, follow your machine’s manual.

Prepare the machine without pulling the recoil starter: steps 1 to 3 of solution 1 on the Honda, 1 to 5 on the Husqvarna, 1 to 6 on the Toro.

  1. Plug the outdoor extension cord into the machine first, then into the outlet.
  2. Hold the starter button: 15 seconds at most according to the Honda manual, 5 seconds according to the Husqvarna and Toro manuals.
  3. If the engine doesn’t start, wait before trying again: 10 seconds for Honda, 1 minute for Husqvarna and Toro.
  4. Once the engine is running, release the button; on the Husqvarna, slowly move the choke back to OFF.
  5. Unplug the cord at the outlet first, then at the machine.

If the starter does nothing, Honda suggests another outlet, another extension cord or the recoil starter.

Frozen recoil rope: Husqvarna advises pulling it out slowly as far as it goes, releasing it, then trying again or switching to the electric starter.

Solution 4: replace stale gas

Toro says not to keep gas longer than 30 days. A stabilizer won’t revive gas that has already gone stale (Honda).

Drain the carburetor on a Honda HS720

  1. Work outdoors, with the engine off and cold.
  2. Put a gas container under the carburetor drain tube.
  3. Set the fuel valve to ON.
  4. Using a long flat screwdriver through the rear left access hole, loosen the carburetor drain screw until gas flows out.
  5. Let the tank drain completely.
  6. Tighten the drain screw.
  7. Fill the tank with fresh gas.

Go back to solution 1: the engine should start on the fresh gas. On a Husqvarna or a Toro, follow the manual’s draining procedure.

Good to know: Honda and Husqvarna accept 10% ethanol at most (E10). Take the drained gas to an approved collection point (Husqvarna).

Solution 5: check the spark plug

Work with the engine cold: the muffler stays hot (Honda). Use the plug type and gap from your manual; the wrong plug can damage the engine (Honda).

  1. Remove the spark plug cap.
  2. Unscrew the spark plug with a spark plug wrench.
  3. Inspect it: according to Toro, a pitted, fouled or cracked plug should be replaced.
  4. On a Husqvarna, clean a plug that is merely dirty.
  5. Adjust the gap if needed: 0.028 to 0.031 in (0.7 to 0.8 mm) on the Honda HS720, 0.030 in (0.76 mm) on the Husqvarna ST 224, ST 227 and ST 230.
  6. For a replacement, use NGK BPR5ES on the Honda HS720 and F6RTC on those Husqvarnas.
  7. Thread the plug in by hand until it seats, then tighten with the wrench: 1/8 to 1/4 turn if it has been used before, 1/2 turn if it is new (Honda).
  8. Put the cap back on the spark plug.

Go back to solution 1: the engine should start.

fraise-a-neige-ne-demarre-pas-300x169 Snow Blower Won't Start: What to Check Before the Shop?

AEG spark plug wrench, 3 sockets 14-16-21 mm

Spark plug wrench with three socket sizes. It removes and refits plugs without damaging the insulator.

fraise-a-neige-ne-demarre-pas-2-1024x576 Snow Blower Won't Start: What to Check Before the Shop?
Replace a pitted, fouled or cracked spark plug before restarting the engine.

If nothing works

Stop if the engine still won’t start after these checks, or if you find a gas smell from a flooded engine, a damaged cord, or a jammed rope or starter.

Honda points you to its dealer, Toro and Briggs & Stratton to a dealer, Husqvarna to an authorized service center. Carburetor cleaning or replacement is shop work.

See also our guides generator won’t start, leaf blower won’t start and chainsaw won’t start.

Take better care of your snow blower: our toolbox

A fuel stabilizer in fresh gas, a clean fuel can, gloves and eye protection help you prepare for next season; they do not replace your manual.

  • STA-BIL fuel stabilizer for petrol enginesAdditive to pour into fresh petrol to protect it from ageing while the machine is stored. It helps the engine start easily again in spring.AmazonSee at Amazon
  • Valpro 5 L steel petrol jerry canFive-litre metal can with a safety pin, suitable for all fuels. Use it to drain the old petrol from the mower and to store the fresh petrol.AmazonSee at Amazon
  • Mechanix Wear Original Covert mechanic glovesClose-fitting work gloves that protect the hands when working under the bonnet. They keep a good grip on tools and clamps.AmazonSee at Amazon
  • 3M Command 2890SC safety gogglesGoggles that protect the eyes from splashes and dust. Useful when sanding, polishing or handling solvents.AmazonSee at Amazon

Frequently asked questions

Why won’t my snow blower start after the summer?

The gas left in the machine may have gone stale: Honda, Toro and Briggs & Stratton say 30 days. Drain the tank and carburetor, then refill with fresh gas (Honda HS720 procedure above).

How do you start a snow blower in very cold weather?

Set the choke to your brand’s cold position: CLOSED on a Honda, FULL on a Husqvarna, Choke on a Toro. On the Toro Power Max 724 OE and 826 OE, press the primer 4 times below 15 °F (-9 °C).

Should you drain the gas from a snow blower for the summer?

Yes, says Honda: drain the tank and carburetor, or run the engine dry, after more than 3 months of storage. Toro prefers a stabilizer in the last tank, then running the engine until it runs out of gas.

How can you tell if a snow blower’s spark plug is bad?

A pitted, fouled or cracked plug should be replaced, according to Toro. Honda calls for a replacement every 150 hours on the HS720.