Your generator won’t start, whether you pull the cord or press the electric start button. According to Briggs & Stratton, the most common cause is old or dirty gasoline. Still, begin with the engine switch, the fuel valve and the oil: you can check all three without tools.
Common symptoms and causes
- Engine switch left in the off position.
- Fuel valve or tank cap vent lever closed.
- Empty fuel tank.
- Old gasoline, stored without a stabilizer.
- Low oil level: the low-oil shutdown (Oil Alert on Honda units) stops the engine.
- Spark plug fouled, worn, wrongly gapped or flooded with fuel.
- Dirty or clogged air filter.
- Dirty carburetor, restricted fuel strainer or faulty valves, which a repair shop should handle.
Before you start
Work outdoors, with the engine off and cold and the generator on level ground. Get a spark plug wrench and the manual for your model.
Warning: the engine gives off carbon monoxide (CO). Always set the generator up outdoors and never run it in an enclosed space, including a sunroom, a garage or a basement.
Headaches, nausea or vomiting, severe tiredness and feeling unwell, especially when several people near an engine or a combustion appliance are affected, should make you think of CO. If that happens, ventilate by opening doors and windows, switch the appliance off if you can, get everyone out and call your local emergency services.
Warning: refuel outdoors, in a well-ventilated spot, with the engine off and cooled down. Keep heat, sparks and flames well away and wipe up spilled gasoline at once.
Warning: stop the engine and wait until it has stopped completely before you work on anything. This procedure does not replace a diagnosis at a workshop.
Warning: unplug every appliance connected to the generator. Unplug a device from the mains before opening it; never work on a device that is plugged in; the capacitors in some devices (TVs, microwave ovens, power supplies) stay charged after unplugging, so do not touch them.
Solution 1: check the switch, the valve and the fuel
The Honda manual and Briggs & Stratton both list these oversights among the causes of a no-start.
- Set the engine switch to
ON. - On the Honda EU2200i, also set the fuel tank cap vent lever to
ON. - Check that the fuel valve is open and clean.
- Check the fuel level and refuel if the tank is empty.
For the choke position, see the manual for your model. The engine should then start.
Solution 2: check the oil level
On Honda generators, the Oil Alert system shuts the engine down when the oil level is too low. Check the oil with the engine cold and the generator level. If the level is correct, go on to solution 3.
- Wait until the engine is cold.
- Check the oil level and appearance.
- If the level is low, set the engine switch to
OFF. - Then add engine oil.
- Set the switch back to
ON. - Restart the engine.

For the oil type and quantity, see the manual for your model. The engine should start and keep running.
Good to know: Briggs & Stratton recommends checking the oil before each use. On its Vanguard engines, it advises changing it every 25 hours or every season.
Solution 3: replace old gasoline
According to Briggs & Stratton, gasoline starts to break down after about a month. The Honda manual lists aged gasoline, stored untreated, among the causes of a no-start. The remedy: drain the tank and the carburetor, then refill.
Warning: drain the fuel outdoors, into a suitable container, away from any flame or spark.
- Drain the fuel tank.
- Drain the carburetor.
- Refill with fresh gasoline.
- On the Honda EU2200i, do not fill above the upper red mark on the fuel strainer.
For draining the carburetor and the fuel your engine requires, see the manual for your model. With fresh gasoline, the engine should start.
Tip: if the generator will sit unused for several weeks, a fuel stabilizer helps keep the gasoline in good shape, according to Briggs & Stratton.
Here is a fuel stabilizer to add to the gasoline before storage.

STA-BIL fuel stabilizer for petrol engines
Additive to pour into fresh petrol to protect it from ageing while the machine is stored. It helps the engine start easily again in spring.
- AmazonSee at Amazon
Solution 4: check, clean or replace the spark plug
The procedure follows the Honda EU2200i manual. Access may differ on your model.
- Let the engine cool down.
- Remove the maintenance cover.
- Check that the plug cap and the plug lead are neither disconnected nor dirty.
- Disconnect the spark plug cap.
- Clear away any dirt around the spark plug.
- Unscrew the spark plug with a spark plug wrench.
- If the plug is wet with gasoline, dry it and put it back.
- If it is fouled or faulty, replace it.
- If it is in good condition but wrongly gapped, adjust the gap.

For the gap value, see the manual for your model. The Honda EU2200i uses an NGK CR5HSB spark plug.
Reassemble in reverse order before you try again. The engine should start.
To unscrew the plug without damaging the thread, a suitable spark plug wrench helps.

AEG spark plug wrench, 3 sockets 14-16-21 mm
Spark plug wrench with three socket sizes. It removes and refits plugs without damaging the insulator.
- AmazonSee at Amazon
Good to know: Briggs & Stratton recommends replacing the spark plug every season or every 25 hours.
Solution 5: clean or replace the air filter
Briggs & Stratton lists a dirty or clogged air filter among the causes of a no-start.
- Check the condition of the air filter.
- Clean it if it is dirty.
- Replace it if it is clogged.
For access to the filter and how to clean it, see the manual for your model. Refit the filter before you try again: the engine should start.
For other four-stroke garden engines, see also our guides on the lawn mower that won’t start and the tiller that won’t start.
If nothing works
Stop once you have checked the fuel, the oil, the spark plug and the air filter. A dirty carburetor, a restricted fuel strainer, an ignition fault, stuck valves or a compression problem are jobs for an authorized dealer of the brand, Honda or Briggs & Stratton for example.
Does your generator have an electric starter? See the manual for your model for how to check the battery.
Good to know: on Honda models fitted with the CO-MINDER system, a high carbon monoxide level shuts the engine down. Move the generator into the open air, then press the reset button to restart it.
Take better care of your generator: our toolbox
These accessories protect your setup and make routine maintenance easier.
- X-Sense XC01-R standalone carbon monoxide detectorSounds an alarm when carbon monoxide builds up in a room, a gas you cannot see or smell. Useful near any heating appliance that burns fuel.AmazonSee at Amazon
- STA-BIL fuel stabilizer for petrol enginesAdditive to pour into fresh petrol to protect it from ageing while the machine is stored. It helps the engine start easily again in spring.AmazonSee at Amazon
- AEG spark plug wrench, 3 sockets 14-16-21 mmSpark plug wrench with three socket sizes. It removes and refits plugs without damaging the insulator.AmazonSee at Amazon
- Valpro 5 L steel petrol jerry canFive-litre metal can with a safety pin, suitable for all fuels. Use it to drain the old petrol from the mower and to store the fresh petrol.AmazonSee at Amazon
- CTEK MXS 5.0 12 V battery charger with temperature compensationRecharges a car battery slowly and automatically, and adjusts the charge to the outside temperature. Can stay connected to maintain the battery.AmazonSee at Amazon
- Mechanix Wear Original Covert mechanic glovesClose-fitting work gloves that protect the hands when working under the bonnet. They keep a good grip on tools and clamps.AmazonSee at Amazon
Frequently asked questions
Why won’t my generator start?
According to Briggs & Stratton, the most common cause is old or dirty gasoline. Check the engine switch, the fuel valve and the fuel level first, then the oil, the spark plug and the air filter. If all of that is fine, the carburetor, the fuel strainer or the valves are a job for an authorized dealer.
How can I tell if a generator’s spark plug is dead?
Take it out: if it is fouled or faulty, replace it. If it is wet with gasoline, it is not dead, the engine is flooded: dry it and put it back. Briggs & Stratton recommends replacing it every season or every 25 hours.
Can you run a generator in a garage?
No. A generator is for outdoor use only, never in a garage, a basement, a sunroom or any enclosed space, because of carbon monoxide. Headaches, nausea or severe tiredness are warning signs: ventilate, get everyone out and call your local emergency services.
Share this content: